The Passport V offers a comprehensive range of options that make it well-suited for most hospital departments.

The flexible feature-set includes your choice of CO 2 and SpO2 technologies. Additional offerings such as multiple invasive pressures, external device interfacing and a secondary display solution are also available for increased monitoring of your more critical patients.

The Passport V has a straightforward and predictable interface, enabling you to easily perform functions and optimize the presentation of patient information. The large, vibrant display with vivid colors allows you to quickly assess patient data. Passport V features single-touch quick action keys and a Navigator Knob used to swiftly move the cursor within and between menus.

Expansion of monitored parameters is automatic, so as you add or remove patient cables, the display will adjust accordingly. A fitting solution right into the O.R. Performance and flexibility make Passport V an ideal fit for peri-anesthesia areas. When paired with our well-known Gas Module 3, Passport V is an excellent choice for the operating room. Additionally, options for advanced cardiac surveillance enable you to extend monitoring into the postoperative environment.

Transport without complexity. With a one-touch mechanism, the monitor is instantly disengaged from the wall mount or rolling stand and ready for transport, patient cables and all.

Specifications

Physical Dimensions

  • Monitor Size: 11.2" (H) x 5.5" (D) x 11.8" (W) 28.5 cm (H) x 14.0 cm (D) x 30.0 cm (W)
  • Weight: 11 lbs (5.0 kg) (Standard configuration, including one battery, recorder)

Input/Output Communications ECG Analog Output Specification

  • Bandwidth (-3 dB referenced to 10 Hz): 0.5 to100 Hz
Maximum
  • Transmission Delay: ≤25 ms (with notch on)
Sensitivity
  • (referenced to 10 Hz): 1 V/mV of input, 10%
Pacer Enhancement
  • Amplitude: +5 V 5%
  • Width: 2 ms 10%

Communication Protocols

  • DIAP Communication Protocol
  • Gas Module Communication Protocol

Electrical Ratings

  • Power Supply: AC power, battery
  • AC Mains Power Source
  • AC Power: 100 - 240 VAC (10%)
  • Current: 1.2 - 0.6 Amps
  • AC Input Power Frequency: 50 Hz/60 Hz

Environmental Conditions

Temperature Range
  • Operating: 0 degrees C to 40 degrees C
  • Non-operating (storage): -20 degrees C to 60 degrees C
Humidity Range
  • Operating: 15% to 95%, non-condensing
  • Non-operating (storage): 10% to 95%, non-condensing
Altitude Range
  • Operating: (-1,000 to 9,841 feet ASL)
  • 1,051 hPa to 700 hPa (788 mmHg to 525 mmHg)
  • Non-operating (storage): (-1,000 to 15,000 feet ASL)
  • 1,051 hPa to 571 hPa (788 mmHg to 428 mmHg)