The Tidal Wave incorporates rugged, solid-state, mainstream CAPNOSTAT® sensor technology and is designed to monitor CO2 in virtually any veterinary clinical setting. A hand-held monitor with full graphics capability.  Features : Y-site probe included  Offering ... [Full Description]

back to top
Description

The Tidal Wave incorporates rugged, solid-state, mainstream CAPNOSTAT® sensor technology and is designed to monitor CO2 in virtually any veterinary clinical setting. A hand-held monitor with full graphics capability. 

Features:

  • Y-site probe included 
  • Offering accurate, reliable monitoring in a convenient, portable package.
  • Ideal for use in emergency and transport settings, and other alternate site monitoring situations.
  • Hand-held mainstream & sidestream capnograph
  • 30 minute on-screen graphic trend available for assessing outcome of therapeutic intervention
  • Visual and Audible "No Respiration" alert provides for a higher level of patient safety during transport and other alternate site monitoring situations
  • Display is visible in any lighting condition - from total darkness to bright sunlight
  • User replaceable disposable and rechargeable battery packs eliminate the need to wait while batteries are charging.
  • Easy user CO2 calibration
  • Available with SpO2

Mainstream vs. Sidestream:

  • Mainstream:  Plug into circuit and get a sample from infrared light to read CO2 lines.
  • Sidestream:  Get a sample line out of the circuit and run through the machine.

Overview of Differences between Mainstream and
Sidestream Capnography

A capnometer, by definition is either diverting (i.e., sidestream) or non-diverting (i.e., mainstream). A diverting capnometer transports a portion of a patient’s respired gases from the sampling site, through a sampling tube, to the sensor whereas a non-diverting capnometer does not transport gas away from
the sampling site [6,7]. In other words, one can view the difference between mainstream (non-diverting) capnography and sidestream (diverting) capnography as clinically measuring carbon dioxide at the sample site versus measuring carbon dioxide in the monitor distant from the sample site.

Four Optional Configurations:

  • Tidal Wave Model 610: Hand-Held Mainstream Capnograph
    • Please note this product has been discontinued 
  • Tidal Wave Model 615: Hand-Held Mainstream & Sidestream Capnograph
  • Tidal Wave Sp Model 710: Hand-Held Mainstream Capnograph/Pulse Oximeter
  • Tidal Wave Sp model 715: Hand-Held Mainstream & Sidestream Capnograph/Pulse Oximeter
back to top
Specifications

SPECIFICATIONS:

CAPNOGRAPH

  • Initialization Time: Capnograph within 15 seconds, full specifications within 60 seconds
  • Capnostat® Mainstream CO2 Sensor:
    • Size: 1.30"H x 1.67"W x .85"D | 3.30 x 4.24 x 2.16 cm
    • Weight: .64 oz | 18 gm - cable excluded
    • Shock Resistance: Withstands repeated 6 ft. drops
  • CO2
    • Range: 0-150 mm Hg, 0-19.7%, 0-20 kPa at 760 mm Hg Pb
    • Accuracy: ±2 mm Hg (0-40 mm Hg) | ±5% of reading (41-70 mm Hg) | ±8% of reading (71-100 mm Hg)
    • Resolution: 1 mm Hg
    • Response Time: 60 ms
    • Units: mm Hg, kPa or %
    • Compensations: N2O & 02 (selectable), Pb (automatic)
    • Capnograph: Selectable sweep speed
  • Respiratory Rate:
    • Accuracy: ±1 bpm
    • Range: 0-150 bpm
    • Resolution: 1 bpm
  • Sampling Flow Rate (model 615 & 715 only): 180 ml/min (for non-intubated patients) Response time is less than 200 ms at 180 ml/min flow

PULSE OXIMETER

  • Sp02:
    • Range: 0-100%
    • Accuracy: ±2% SpO2 (for 70-100% SpO2) (1SD), Unspecified for 0-69% SpO2
    • Resolution: 1%
  • Pulse Rate:
    • Range: 30-250 bpm
    • Accuracy: ± of full scale
    • Resolution: 1 bpm
    • Averaging: 8 sec.

GENERAL

  • Display:
    • Size: 2.2"W x 1.1"H | 5.6 x 2.8 cm

PHYSICAL

  • Size: 7.9"H x 3.25"W x 1.5"D | 20 x 8.25 x 3.8 cm
  • Weight: 28 oz

ELECTRICAL:

  • Input: 100-250 VAC, 50-60 Hz
  • Battery: Nickel-metal-hydride: 4.5-hr, Standard AA lithium: 5.5-hr life